✔ ISO 9001 · 14001 · 22000 Certified📍 Vadodara, Gujarat · Pan-India Supply
Free Engineering Tools

Water Treatment Dosing CalculatorsInline · Cooling Tower · RO · Boiler · Biocide

Five free calculators for plant engineers: continuous chemical dosing, cooling tower blowdown and makeup, RO antiscalant, boiler oxygen scavenger and biocide slug dosing. Each shows its formula so you can check the maths. Results update instantly as you type.

Core Formula
kg/day= m³/h × 24 × ppm ÷ 1000
E= 0.00153 × R × ΔT
B= E ÷ (CoC − 1)
Na₂SO₃≈ 7.88 × ppm O₂
MODULE 01

Continuous Flow-Proportional Dosing

Daily chemical requirement and metering-pump rate for continuous inline dosing.

Active chemical / day0 kg
Product required / day0 kg
Product volume / day0 L
Metering pump rate0 L/h
Product / month (30 d)0 kg
Active (kg/day) = Q × h × ppm ÷ 1000
Product = Active ÷ (active % ÷ 100)
Volume = Product ÷ SG · Pump = Volume ÷ h
MODULE 02

Cooling Tower Evaporation, Blowdown & Inhibitor Dosing

Cooling tower mass balance from recirculation rate, temperature drop and cycles of concentration (CoC).

Evaporation loss0 m³/h
Blowdown0 m³/h
Makeup water0 m³/h
Inhibitor product / day0 kg
Inhibitor volume / day0 L
E = 0.00153 × R × ΔT · B = E ÷ (CoC − 1)
M = E + B (drift ignored)
Product (kg/day) = M × 24 × ppm ÷ 1000 ÷ active%
MODULE 03

Reverse Osmosis (RO) Antiscalant Dosing

Neat antiscalant consumption for your RO feed flow.

Antiscalant feed rate0 kg/h
Antiscalant / day0 kg
Antiscalant / month (30 d)0 kg
Feed (kg/h) = Q (m³/h) × ppm ÷ 1000
Daily = Feed × 24
MODULE 04

Boiler Oxygen Scavenger & Scale Inhibitor Dosing

Feedwater demand, theoretical sodium sulfite demand and scale-inhibitor feed for steam boilers.

Feedwater demand0 t/h
Blowdown flow0 t/h
Sodium sulfite (100%) / day0 kg
Scale inhibitor product / day0 kg
F = Steam ÷ (1 − BD%) · Blowdown = F − Steam
Na₂SO₃ = F × 24 × O₂ × 7.88 × SF ÷ 1000
Inhibitor = F × 24 × ppm ÷ 1000 ÷ conc%
MODULE 05

Biocide Shock / Slug Dosing

One-time slug dose for microbial and bio-slime knockdown in cooling towers or closed loops.

Active biocide required0 kg
Product per slug0 kg
Product volume per slug0 L
Active (kg) = V (m³) × ppm ÷ 1000
Product = Active ÷ active% · Volume = Product ÷ SG

These calculators give estimates based on ideal steady-state conditions. Confirm final dosing with jar testing or our technical chemists.

Talk to Our Chemists

Need a Dosing Programme? Ask Our Chemists.

Send your water analysis and operating data for a free dosage simulation and product recommendation.

FAQ

Frequently Asked Questions

How do I calculate chemical dosage for water treatment?

Product required (kg/day) = flow (m³/h) × 24 × dose (ppm) ÷ 1000 ÷ (product active % ÷ 100). For example, 100 m³/h at 10 ppm active using a 50% product needs 48 kg/day.

How do I calculate cooling tower evaporation and blowdown?

Evaporation (m³/h) ≈ 0.00153 × recirculation (m³/h) × ΔT (°C). Blowdown = evaporation ÷ (cycles of concentration − 1), and makeup = evaporation + blowdown (drift ignored).

How much sodium sulfite is needed to remove dissolved oxygen?

Theoretically 7.88 ppm of sodium sulfite per 1 ppm of dissolved oxygen, multiplied by a safety factor of about 1.2–1.5 for excess residual.

How is a biocide slug dose calculated?

Active biocide (kg) = system volume (m³) × target ppm ÷ 1000. Divide by the product's active fraction to get the product quantity.